Setting up a brand-new shower unit 12168
Installing a New Shower Unit
An effective shower setup requires cautious preparation and a lot of work. For the most part, you will need to do 3 kinds of tasks: framing walls, setting up the pipes, and completing walls.
Preparation
Firstly, you should choose the kind of shower that you wish to install. It is essential to determine whether the picked shower is capable of handling specific systems and can control a safe level of water through the boiler. The majority of shower units nowadays are developed to be flexible to various water pressures (such as stored warm water and cold mains).
It is also important to take into account the water pressure and the preparation of the piping and drain for the shower
Different Kinds of Shower Units
Push-on Mixer: The pipe and spray parts of the push-on mixer shower system can be linked to the bath tap based on your requirement, and the water temperature can be adjusted by means of the taps. Push-on mixers are inexpensive and exceptionally basic to install. However, although the hose pipe connection is basic, it is easily dislodged. Furthermore, it is inconvenient to change the temperature.
Bath/ Shower Mixer: The hose and spray of this kind of shower are combined with a bath mixer tap, and the temperature can be changed through the bath taps. It is a really cheap option and no extra pipes is included. Nevertheless, the bath/shower mixers likewise suffer from inconvenient temperature level control alternatives.
Manual Mixer: The hose and spray of a manual mixer shower unit belong of the wall system and the hot and cold water supplies are connected to a single valve The temperature level and pressure of the water are controlled through either one or a range of knobs (in more expensive showers). Although temperature level control is a lot easier in manual mixer types, they are more costly than the formerly mentioned mixers. They likewise require additional plumbing of hot and cold water system pipes.
Thermostatic Mixer: The pipe and spray of this shower type are a part of the wall unit and the hot and cold water products are connected to a single valve here too. It is complete with a built-in stabiliser to self-adjust the water temperature level and to avoid it from becoming too hot. Among the most significant benefits of a thermostatic mixer shower type includes convenient temperature control. However, it is the most pricey of the different mixer options.
Power Shower: A power shower is a single system consisting of a powerful electrical pump that can changing both the water pressure and temperature. This type of shower can be fitted if there is supply of water from a cold water tank and a warm water cylinder. A power shower makes the modification of both pressure and temperature simple. On the other hand, it is unsuitable for water warmed straight by the shower or where the water is supplied by a mix boiler under mains pressure.
Electric Shower: An electric shower is plumbed into a mains cold water supply and it heats the water electrically. It is necessary to note that for this shower type to be set up, the mains pressure requires to be at least 0.7 kg/sq cm (10lb/sq in). The unit permits the temperature and pressure to be changed by means of a knob. Models with temperature stabilisers are much better as they remain untouched by other taps in other places in usage within the home. A major disadvantage of electrical showers is that the control knob just allows for the option of high temperatures at less pressure, or lower temperature levels at a greater pressure. This is troublesome in the winter when the spray is often weak and the mains water is cooler. However, this problem is tackled in some designs which are offered with a winter/summer setting.
Method
Depending on the kind of shower you want to install, the shower head should either be fitted in order to avoid its contact with the water in the bath below or the base tray, or it should have a check valve.
Before starting, it is advisable to mark the positions of the shower head and control, and to prepare the pipe-work included. In addition, the drain system to remove the Cranbourne residential plumber waste water will need to be planned. Both positions of the cable route and the shower switch will also need to be considered if an instantaneous or electrical shower system is being installed.
Use the guideline guide offered with the shower system to fit the shower control.
Before fitting the pipelines that will supply the water to the shower system, it is important to cut off the water supply. In order to secure the pipes, they should be given a waterproof covering and likewise fitted with separating valves. The pipes can then be buried into the wall and plastered over to neaten the general look.
Fit the Hastings plumbing repairs base tray, shower head, and fittings.
Connect the main shower control to the pipes that will be providing the water (This may require a female screw thread adapter).
Reconnect the supply of water and test the pipelines for any leakages, as some may require tightening.
If you are setting up an electrical shower, remember to switch off the electricity supply before making any electrical connections. Once these connections have been made (there ought to be guidance within the instruction manual), the power supply can be switched back on.
Adjusting Water Pressure to Match Your Shower
The cold water reservoir can be raised to a higher height (sometimes just 150mm (6inches)) by fitting a strong wooden support below it-- perhaps made up of struts and blockboards. If you select this choice, the main and distribution pipes will likewise have to be raised to satisfy the brand-new height of the reservoir.
Alternatively, a booster pump (a single pump or a dual/twin pump) can be fitted. Whichever type is chosen, it should be linked into the power supply in order to operate.
Piping and Drainage
It is best to utilize 15mm size supply pipelines, and make the go to the shower as brief and straight as possible so regarding keep maximum pressure and minimise heat loss. Additionally, by reducing making use of elbows for pipe corners, you can decrease the resistance in the circulation of the water system. You can accomplish this by bending the pipes instead.
Most Common Mistakes

# Violating or disregarding regional code restrictions.
# Using pipes that are too small.
# Connecting copper to galvanized without utilizing a brass or dielectric fitting between the two.
# Not using tape or pipeline substance at threaded joints.
# Not leveling your components when setting up them.
# Not setting up an air space filling for fixtures.
# Cutting supply stub outs too short to set up the shutoff valves onto after the finished wall remains in place.
# Not properly lining up tubing into fittings or stop valves. (Requiring the nut onto the compression ring at an angle when the tubing is at an angle will cause a leak.)
# When turning the water back on in your house, constantly run the outdoors hose valve or flush your toilets to bleed dirt and air from the lines. This particles can cause issues in your sink faucets and other plumbing trim.